Applications that are not recommended Run-out

Run-out should be less than 0.02 mm.

Drilling on Counter

slanted Plunging Boring Max. 0.02 mm

surface θ θ > 6°

Instruction o f clamping head

Ideal : )0.02mm Acceptable : )0.05mm Not acceptable: >0.05mm

Fig. #3 Fig. #2 Fig. #1
Procedure
ᆰClean the clamping areas on the drill body and the head with an airNote #1: If the clamping torque is not equally
blast, lubricate them, and put the drill head in the pocket.applied on the right and the left sides of the
ᆱSet the clamping key in the groove on the drill head. Push the headdrill head, there may be a gap between the
toward the pocket with equal torque on the right and the left sides,head and the body, which increases the run-
and turn the clamping key to clamp the head completely. (Fig. #1)out of the head.
Be sure that there is no gap between the bottom of the head andNote #2: Low accuracy in holding the drill
body may affect the run-out. If the run-out is
the drill body. A shim in the thickness of around 0.01 mm is useful to large, check the accuracy in holding the drill
check the gap. (Fig. #2)body.

ᆳIf there is a gap thicker than 0.01 mm, unclamp the head and return to procedure No. ᆰ ᆴCheck the run-out at the margin of the drill head. Run-out must be less than 0.05 mm. (Fig. #3) (Recommended value: less than 0.02

mm)

If the run-out exceeds 0.05 mm, unclamp the head and return to

procedure No. ᆰ .

KEY FOR MEASURING HEAD RELEASE TORQUE

The release torque in unclamping a head is measured with a torque driver to determine the body’s tool life. Please refer to the below for the standard release torque value which indicates the end of tool life (The value less than the standard should be judged as the end of tool life).

Head designationRelease torque value to indicate tool replacement (N・m)(cN・M)
DMP100-1090.220
DMP110-1190.220
DMP120-1290.2525
DMP130-1390.2525
DMP140-1490.330
DMP150-1590.330
DMP160-1690.3535
DMP170-1790.3535
DMP180-1890.440
DMP190-1990.440

torque driver.