Specification M10×1.5 UNC Chamfer: 5P Tap dril size 8.5mm(ref.)
Oxide
Low carbon steels Medium carbon steels
(m/min) (m/min)
Blister Pack
Product Features How to use IHT
both through hole and blind hole. size by using drills (note: For drill sizes, refer to drill sizes
When hand tapping, always use Machine tapping with drilling
Through hole = 5 thread type Blind hole = 2 thread type tap wrench machine
■Table for bored and drilled hole sizes unit:mm
| Minor | Diameter of Internal Thre | ad Size | |||
| Size | Minimum | Maximum | Tolerance | Drill Size Th Ena | read ement |
| Tolerance | 6H(2nd Class) | 7H(3rd Class) | g | ||
| M3×0.5 | 2.459 | 2.599 | 2.639 | 2.6(2.5) 74% | (92%) |
| M4×0.7 | 3.242 | 3.422 | 3.466 | 3.4(3.3) 79% | (92%) |
| M5×0.8 | 4.134 | 4.344 | 4.384 | 4.3(4.2) 81% | (92%) |
| M6×1 | 4.917 | 5.153 | 5.217 | 5.1(5.0) 83% | (92%) |
| M8×1.25 | 6.647 | 6.912 | 6.982 | 6.9(6.8) 91% | (89%) |
| M10×1.5 | 8.376 | 8.676 | 8.751 | 8.6(8.5) 86% | (92%) |
note1) Recommended drill sizes shown in this table are for internal threads of 7H class(3rd class), and are selected from the standard drills available in the market. note2) Drill sizes shown in brackets in this table are for such case as the drilling has oversize cutting tendency or for internal threads of 6H class(2nd class).