| Formula: Programme Feed Rate (fz) | h | = Average chip thickness | Formula: Average Chip Thickness (hm) |
| m | |||
| a = Depth of cut | |||
| p |
d f = Feed per tooth a
| f = h | x | z | h | = f x | p | |||
| z | m | m | z | |||||
| a | = Insert diameter (45mm) | |||||||
| p | d | d |
Theoretical Diameter for all high feed insert sizes = 45mm
Calculation of the average chip thickness in relation with the ae (Radial Engagement) if ae is less than 50% of Dia.
| Formula: Programme Feed Rate (fz) | h | = Average chip thickness | Formula: Average Chip Thickness (hm) |
| m | |||
| a = Radial engagement | |||
| e |
d f = Feed per tooth a
| f = h | x | z | h | = f x | e | |||
| z | m | a | = Cutter diameter | m | z | |||
| e | d | d |
D Ramping
Insert Effective Facing Angle ap max Max
Item Description D * Helical Hole Helical /
Size Cutting a Pitch min. - max. RPM
Diameter A ° B ° Linear
| 8000VXD92-100R-12 | 87,95 | 106,00 | 87,95 | 0.31 0.47 | 192 | 210 | 1,80 | 10800 | |
| 8000VXD92-125R-12 | 112,95 | 131,00 | 112,95 | 0.24 0.36 | 242 | 260 | 1,80 | 9200 | |
| 12mm | 8000VXD92-160R-12 | 147,95 | 166,00 | 147,95 | 0.18 0.28 | 312 | 330 | 1,80 | 7800 |
| 8000VXD92-200R-12 | 187,95 | 206,00 | 187,95 | 0.14 0.21 | 392 | 410 | 1,80 | 6800 | |
| 8000VXD92-250R-12 | 237,95 | 256,00 | 237,95 | 0.11 0.17 | 492 | 510 | 1,80 | 5900 | |
| 8000VXE92-100R-16 | 82,15 | 106,00 | 82,15 | 0.39 0.47 | 186 | 210 | 2,50 | 10800 | |
| 8000VXE92-125R-16 | 107,15 | 131,00 | 107,15 | 0.29 0.36 | 236 | 260 | 2,50 | 9200 | |
| 16mm | 8000VXE92-160R-16 | 142,15 | 166,00 | 142,15 | 0.22 0.27 | 306 | 330 | 2,50 | 7800 |
| 8000VXE92-200R-16 | 182,15 | 206,00 | 182,15 | 0.17 0.20 | 386 | 410 | 2,50 | 6800 | |
| 8000VXE92-250R-16 | 232,15 | 256,00 | 232,15 | 0.13 0.16 | 486 | 510 | 2,50 | 5900 |
* Denotes non stock items.
Ramping Helical Interpolation Flat
Facing Pitch
A B
Ramp angle A uses one outside cutting edge only. Ramp angle B uses two cutting edges (one outside and one inside edge). A = max ramp angle utilising full face contact B = max ramp angle utilising full contact + internal corner radius