Thread M D i Technical information 9.2. Quick-change adapters with safety clutch for taps RECOMMENDED TORQUE VALUES FOR TAPPED MATERIALS WITH RM=1000 MPA 35 Thread Torque M [Nm] 30 3 0,5 4 1,2 5 2 25 6 4 8 8 10 16 20 12 22 14 36 16 40 15 18 63 20 70 22 80 24 125 10 27 140 30 220 33 240 20 40 60 80 100 120 140 160 180 200 Torque [Nm] The values given are approximate and may be different depending on specific operating conditions 9.3. ER collets mounting SHANK RUNOUT MOUNTED IN THE ER COLLET S L D L S 1-1,6 6 0,008 1,6-3 10 0,008 3-6 16 0,008 6-10 25 0,008 10-18 40 0,008 12 18-26 50 0,00826-40600,008 312