5505VX Technical Information

Working Diameter: D = 2 x r2 - (r -a )2 e p

where: D = Working Diameter e

r a r = Cutter radius

p = Axial Depth of Cut a p De

5505VX Technical Information

where: f = Feed per tooth a = Radial Depth of Cut z e

h = Average chip thickness a = Axial Depth of Cut

m p r = Insert radius

Average chip thickness: h

m

()2()2
r2 - r - ar 2 - r - a
ep
h= fxx
mzrr

To find programmed feedrate: f

z h m f = z

( )2 ( )2

r 2 - r - a r 2 - r - a e p x r r

Please do not try to remove

this screw. This screw is

glued into the body to keep

the inserts in the correct

position.