PreHole
| ICP/ ICM/ ICN | ICK | HCP/H3P | FCP/F3P | QCP | ICG | ||||
| Hole | |||||||||
| ICP | ICP/M/N PreHole | ICK PreHole | H#P PreHole | FCP PreHole | QCP PreHole | ICG PreHole | |||
| ICM | |||||||||
| ICN |
ICP ICP ICP ICP ICP ICP
| ICP/M/N PreHole | ICK PreHole | H#P PreHole | FCP PreHole | QCP PreHole | ICG PreHole | |
| ICK |
ICK ICK ICK ICK ICK ICK
| ICP/M/N PreHole | ICK PreHole | H#P PreHole | FCP PreHole | QCP PreHole | ICG PreHole | |
| HCP | ||||||
| H3P |
H#P H#P H#P H#P H#P H#P
| ICP/M/N PreHole | ICK PreHole | H#P PreHole | FCP PreHole | QCP PreHole | ICG PreHole | |
| FCP | ||||||
| F3P |
F#P F#P F#P F#P F#P F#P
| ICP/M/N PreHole | ICK PreHole | H#P PreHole | FCP PreHole | QCP PreHole | ICG PreHole | |
| QCP |
QCP QCP QCP QCP QCPQCP QCP
| ICP/M/N PreHole | ICK PreHole | H#P PreHole | FCP PreHole | QCP PreHole | ICG PreHole | |
| ICG |
ICG ICG ICG ICG ICG ICG
*For proper insert performance and centering, a bigger insert within a 1.0 mm range of the same diameter may be used Drilling Head Coolant Recommendations Mounting Procedure 1
2
3
4
5
Up to 2D Maximum Runout, Misalignment Max 0.02 mm
Max 0.02 mm
The optional K DCN MULTI key enables clamping all currently available SUMOCHAM drilling heads in a 6-26.9 mm diameter range.